Solutions · Industry · Energy, oil & gas
Energy, oil and gas operators run control systems where an outage is a safety problem, not only a data problem. ioSENTRIX tests the path from corporate IT into OT, remote access, control systems and field devices without disrupting operations, and a retest of your fixes is included.
01The short answer
Keeping attackers away from the systems that control physical operations: the boundary between corporate IT and OT, remote and vendor access, ICS and SCADA, field devices and the people who run them. For many operators it also means evidence for NERC CIP and alignment with the ISA/IEC 62443 series.
Attackers want a path from email or the VPN to the systems that run plants, pipelines and substations.
OT testing is agreed in the rules of engagement and done passively, in test environments or in agreed windows.
Each finding comes with evidence of the path and a prioritized recommendation, from segmentation to MFA.
OT (operational technology) security protects the systems that monitor and control physical processes, such as ICS, SCADA, PLCs and HMIs. Availability and safety come first, so testing is planned around operations. Read what is ICS security.
Many control systems were designed for isolated networks, run for decades and cannot be patched quickly, yet they are increasingly connected to corporate IT, the cloud and vendors. Read energy sector cybersecurity challenges.
02See it in action
IT and OT are often tested by different teams. Attackers cross between them. This is how one path from a phishing email to read access on an HMI is found, proven and closed, without sending a single command to the process.
03What your operations and compliance leads see
One team follows the path from corporate IT through the DMZ into OT, so a weakness in one zone is followed into the next.
OT steps are agreed in the rules of engagement. In production, testers stop at proving access; anything riskier is shown in a test environment.
Each step gets its own fix, and the whole path is replayed in the retest to show it no longer works.
Illustrative example. The zones, systems, path and statuses are a composite for explanation only and do not describe any client. Production control systems are not sent commands; scope and limits are agreed in the rules of engagement.
03Threat landscape
Common threats to energy operators, where they land, and how ioSENTRIX tests each one.
| Threat | Where it lands | How ioSENTRIX tests it | Service |
|---|---|---|---|
| Ransomware crossing into OT | Corporate network, the IT/OT DMZ and shared services | Assumed-breach testing that follows the path ransomware operators take from IT toward OT | Red teaming |
| Remote access and VPN | VPNs, jump hosts and remote desktop | Testing of remote access paths, intermediate systems and MFA enforcement | Network security |
| Flat OT networks | Control and plant networks | Segmentation and firewall-rule testing between zones. See network segmentation | ICS / IoT pentest |
| ICS and SCADA exposure | PLCs, HMIs, historians and industrial protocols such as Modbus and DNP3 | Passive analysis and agreed, non-disruptive testing of protocols and services | ICS / IoT pentest |
| IoT and embedded devices | Sensors, RTUs, gateways and smart meters | Firmware, protocol and configuration testing, in the lab where possible | Embedded device pentest |
| Vendor access | Integrators, equipment makers and managed service providers | Review and testing of vendor remote access and shared accounts | Network security |
| Phishing | Operators, engineers and office staff | Phishing simulation and social engineering | Social engineering |
| Cloud SCADA and IIoT | Cloud-hosted SCADA, historians and IIoT dashboards | Cloud configuration review and web and API testing of the platform | Cloud security |
Coverage is agreed per engagement in the written scope. OT testing is non-disruptive and follows the rules of engagement.
04Regulation
The standards that most often call for testing evidence in energy, and what each one says about testing.
Responsible entities with high or medium impact BES Cyber Systems
A paper or active vulnerability assessment at least once every 15 calendar months (Part 3.1); for high impact systems, an active assessment at least once every 36 calendar months where technically feasible (Part 3.2); and documented results with a remediation action plan (Part 3.4). NERC ↗
Responsible entities with high impact, or medium impact with External Routable Connectivity, BES Cyber Systems
For Interactive Remote Access: an Intermediate System, encryption that terminates at it, and multi-factor authentication (Parts 2.1–2.3). Testing shows whether remote access can bypass them. NERC ↗
Asset owners, integrators and product suppliers of industrial automation and control systems
Requirements and processes for implementing and maintaining electronically secure industrial automation and control systems. Testing evidence supports assessment against them. ISA ↗
Orientation, not legal advice. Which standards apply depends on your registration, assets and jurisdiction. CIP standards are revised over time: FERC approved modified CIP standards in 2026 (Order No. 919), so check the version in effect for you. ioSENTRIX performs the testing and writes reports; it does not determine compliance.
05Zones
Zone by zone, from corporate IT to the field.
Internal and external network testing of the business network that OT depends on.
Jump hosts, historians and shared services between IT and OT, tested for credential reuse and routes into OT.
PLCs, HMIs, historians and their protocols, tested passively or in agreed maintenance windows.
RTUs, sensors, gateways and smart meters, with firmware tested in the lab.
VPNs, remote desktop and vendor connections, including MFA and intermediate systems.
Phishing simulation and goal-driven red team exercises, typically 4–6 weeks.
06Independently verified
“The team at ioSENTRIX is professional and highly skilled at their craft.”
“We were impressed with ioSENTRIX's ability to independently validate the security of our customer-facing product.”
07How we help
Described by sector. Clients are never named.
08Insights
09FAQ
Short answers to what security and operations leaders in energy ask us most.
Ask us something elseOT (operational technology) security protects the systems that monitor and control physical processes, such as ICS, SCADA, PLCs and HMIs. Unlike IT, safety and availability come first, so testing is planned around operations. See what is ICS security.
It can be, when it is planned for OT. Scope, timing and limits are agreed in the rules of engagement. We prefer passive analysis, test environments and agreed maintenance windows, and in production we stop at proving access rather than sending commands to control systems.
Not by name. CIP-010-4 Requirement R3 requires vulnerability assessments: a paper or active assessment at least once every 15 calendar months, and for high impact BES Cyber Systems an active assessment at least once every 36 calendar months where technically feasible, with results and a remediation action plan documented. A penetration test can supply active-assessment evidence; your compliance team decides how it maps.
IT testing focuses on data and accounts. OT testing puts safety and availability first and deals with industrial protocols and legacy systems that often cannot be patched quickly, so it relies on passive techniques, test environments and tight rules of engagement. Many attacks start in IT and cross into OT, so we test the boundary between them.
Yes: PLCs, RTUs, HMIs, historians, gateways and their protocols, in the lab where possible and non-disruptively in production. See ICS, IoT and IIoT penetration testing.
Findings can be mapped to the NERC CIP requirements in your scope, such as CIP-005 remote access management and CIP-010 vulnerability assessments, and to the ISA/IEC 62443 series. ioSENTRIX does not determine compliance; your compliance team and auditors do.
It depends on scope and on operational windows. A red team exercise typically takes 4–6 weeks. You receive a written scope, timeline and rules of engagement, agreed with your operations team, before testing starts.
Ready when you are
Tell us about your sites, zones and the standards you report against. We will help you scope a test that is safe for operations.
Takes about a minute.