Solutions · Compliance · FDA 510(k)
Medical device cybersecurity is now part of what FDA reviews in a premarket submission. ioSENTRIX tests your device, firmware, wireless interfaces, apps and cloud the way an attacker would, ties each finding to your threat model, and includes a retest of your fixes so the testing documentation in your submission holds up.
01The requirement
FDA recommends it, and cyber devices carry legal requirements. FDA's final guidance on cybersecurity in medical devices (February 3, 2026) recommends that security testing documentation be submitted in premarket submissions and lists penetration testing among the testing to consider including. For cyber devices, section 524B of the FD&C Act requires a postmarket vulnerability plan, cybersecurity processes and an SBOM.
Alongside threat mitigation, vulnerability and fuzz testing. Guidance is nonbinding.
Plan, processes and SBOM required in the 510(k), De Novo or PMA submission.
FDA asks reports to show tester independence, scope, duration, methods and results.
Medical device penetration testing is an authorized, simulated attack on a device and its system: firmware, wireless and wired interfaces, companion apps, update mechanisms and cloud services. It looks for vulnerabilities an attacker could discover and exploit, and documents them in the form FDA asks for in a premarket submission.
FDA recommends designing cybersecurity in, for example through a secure product development framework (SPDF), with threat modeling, security risk management, an SBOM, security testing throughout development, and a plan for postmarket vulnerabilities. Read FDA's final guidance or our 510(k) and section 524B explainer.
02See it in action
How one security control on a connected device is tested like an attacker would, fixed, retested and documented for your premarket submission.
We start from the threats and controls in your threat model and test whether each control holds, so results trace straight back to your design documentation.
Reports state our independence and expertise, scope, duration, methods and results, the elements FDA's guidance asks penetration test reports to include.
A retest of your fixes is included, so your submission shows each finding assessed, remediated or justified, and confirmed.
Illustrative example. The device, interface and statuses are a composite for explanation only and do not describe any client. Testing uses test units agreed in the rules of engagement, never devices in clinical use.
03Requirement to evidence
What FDA's guidance and section 524B ask for, what ioSENTRIX tests for each, and the evidence that goes into your submission.
| Expectation | What FDA asks | What ioSENTRIX tests | Evidence in your submission |
|---|---|---|---|
| Threat modelGuidance | Threat modeling of the device system, with traceability to the risk assessment, SBOM and testing. | Threat modeling or review of yours, covering every interface and update path. | Threat model and traceability matrix |
| Risk assessmentGuidance | Cybersecurity risk assessment and a security risk management report. | Exploitability assessment of identified risks, proven on test units. | Findings mapped to risk controls |
| SBOM524B(b)(3) | A software bill of materials, including commercial, open-source and off-the-shelf components, required for cyber devices. | SBOM review and software composition analysis of firmware binaries. | SBOM validation and known-vulnerability notes |
| Security testingGuidance | Security requirements, threat mitigation and vulnerability testing (fuzzing, attack surface, chaining, code analysis) and penetration testing. | Embedded device penetration testing, fuzzing of wireless and wired inputs, app and cloud testing. | Reports with independence, scope, duration, methods and results |
| Findings assessmentGuidance | Your assessment of every finding, with rationale for any fix not implemented or deferred, and plans for future releases. | Risk-ranked findings with fix guidance, then a retest of your fixes. | Findings log, retest results and deferral rationale |
| Postmarket524B(b)(1), (b)(2) | For cyber devices: a plan to monitor, identify and address postmarket vulnerabilities, and updates and patches for known unacceptable vulnerabilities. | Testing of the update mechanism, retests of patches and testing after significant changes. | Update-path results and patch retests |
Summarized from FDA, "Cybersecurity in Medical Devices: Quality Management System Considerations and Content of Premarket Submissions," final guidance issued February 3, 2026 (nonbinding recommendations), and section 524B of the FD&C Act as described in that guidance. Orientation, not regulatory advice. FDA decides what evidence is sufficient.
04Timing
Throughout development, as FDA recommends, with an independent penetration test before the design is frozen for submission.
Security requirements and architecture built into the secure product development framework.
Design reviewEvery interface, update path and connected system modeled and risk-assessed.
Threat modelFuzzing, SBOM and binary analysis, and an independent penetration test on test units.
Manual testingFix guidance for each finding, then a retest of your fixes.
Retest includedReports and traceability ready for your 510(k), De Novo or PMA.
Evidence packTesting of updates and patches, and after significant changes.
OngoingThreat model, risk assessment, SBOM and security testing documentation, including penetration test reports, in the premarket submission.
For cyber devices, the 524B(b)(1) plan and timely updates and patches, with testing that confirms each fix.
05Evidence pack
The testing documentation your regulatory team needs for the submission, in one place.
Who tested, their qualifications and their independence from your developers.
Device, firmware, interfaces, apps and cloud in scope, dates and the methods used.
Each finding with evidence, exploitability, potential impact and steps to reproduce.
Software composition results and known vulnerabilities in third-party components.
Fixes retested and recorded, with rationale noted for any deferred finding.
Each result traced to the threat model and risk assessment.
Share it with confidence. The report comes from a CREST-accredited firm that is itself ISO/IEC 27001 certified and SOC 2 Type 2 attested. See our trust center.
06Independently verified
“The team at ioSENTRIX is professional and highly skilled at their craft.”
“We were impressed with ioSENTRIX's ability to independently validate the security of our customer-facing product.”
07How we help
From the first threat model to testing every update after clearance.
08Insights
09FAQ
Short answers to what device makers and regulatory teams ask us most.
Ask us something elseFDA's final guidance, Cybersecurity in Medical Devices: Quality Management System Considerations and Content of Premarket Submissions (February 3, 2026), recommends that security testing documentation be included in premarket submissions, including 510(k)s, and lists penetration testing among the types of testing to consider. FDA asks that penetration test reports state the testers' independence and technical expertise, the scope, duration and methods of testing, and the results. The guidance contains nonbinding recommendations; for cyber devices, section 524B of the FD&C Act adds statutory requirements.
Section 524B(c) of the FD&C Act defines a cyber device as a device that includes software validated, installed or authorized by the sponsor as a device or in a device, has the ability to connect to the internet, and contains technological characteristics that could be vulnerable to cybersecurity threats. FDA's guidance treats firmware and programmable logic as software, and counts any means of connecting to the internet, intended or not.
A submission for a cyber device must include information FDA requires to show it meets section 524B(b): a plan to monitor, identify and address postmarket cybersecurity vulnerabilities and exploits, including coordinated vulnerability disclosure (524B(b)(1)); processes and procedures that provide reasonable assurance the device and related systems are cybersecure, including updates and patches (524B(b)(2)); and a software bill of materials (524B(b)(3)).
The guidance lists, among others: testing of security requirements; threat mitigation testing against your threat models; vulnerability testing such as abuse and misuse cases, malformed and unexpected inputs (robustness and fuzz testing), attack surface analysis, vulnerability chaining, known vulnerability scanning, software composition analysis of binaries and static and dynamic code analysis; and penetration testing.
FDA asks manufacturers to state who performed the testing and what level of independence the testers have from the developers who designed the device, and notes that third parties may sometimes be needed to ensure appropriate independence. For third-party reports, FDA asks for the original report. ioSENTRIX tests as an independent third party.
FDA asks for your assessment of every finding, including the rationale for not implementing or deferring a fix. For remediation deferred to a future release, the submission should contain plans for that release, including the vulnerabilities it will address and anticipated timelines.
No. ioSENTRIX provides the cybersecurity testing, threat modeling, SBOM review and reports that go into your premarket submission. Your regulatory team prepares and submits it, and FDA makes the clearance decision.
Ready when you are
Tell us about your device, its interfaces and your submission date. We will help you scope the right testing and plan it before design freeze.
Takes about a minute.