Medical device penetration testing for FDA 510(k) premarket cybersecurity

Medical device cybersecurity is now part of what FDA reviews in a premarket submission. ioSENTRIX tests your device, firmware, wireless interfaces, apps and cloud the way an attacker would, ties each finding to your threat model, and includes a retest of your fixes so the testing documentation in your submission holds up.

GuidanceFDA premarket cybersecurity guidance (Feb 2026) · FD&C Act section 524B
Who asksFDA reviewers, your regulatory team and hospital customers
What you getIndependent pentest and fuzzing reports, retest included, mapped to your threat model
Reviewed by Omair Manzoor, Founder & CEO, ioSENTRIX · Updated November 2026Key terms: Embedded device security, SBOM, Fuzz testing
Trusted by security teams at

01The requirement

Does the FDA require penetration testing for a 510(k)?

FDA recommends it, and cyber devices carry legal requirements. FDA's final guidance on cybersecurity in medical devices (February 3, 2026) recommends that security testing documentation be submitted in premarket submissions and lists penetration testing among the testing to consider including. For cyber devices, section 524B of the FD&C Act requires a postmarket vulnerability plan, cybersecurity processes and an SBOM.

GuidancePenetration testing recommended

Alongside threat mitigation, vulnerability and fuzz testing. Guidance is nonbinding.

StatuteSection 524B for cyber devices

Plan, processes and SBOM required in the 510(k), De Novo or PMA submission.

ReportIndependence, scope, methods

FDA asks reports to show tester independence, scope, duration, methods and results.

What is medical device penetration testing?

Medical device penetration testing is an authorized, simulated attack on a device and its system: firmware, wireless and wired interfaces, companion apps, update mechanisms and cloud services. It looks for vulnerabilities an attacker could discover and exploit, and documents them in the form FDA asks for in a premarket submission.

What is medical device cybersecurity under FDA guidance?

FDA recommends designing cybersecurity in, for example through a secure product development framework (SPDF), with threat modeling, security risk management, an SBOM, security testing throughout development, and a plan for postmarket vulnerabilities. Read FDA's final guidance or our 510(k) and section 524B explainer.

02See it in action

From design control to premarket evidence

How one security control on a connected device is tested like an attacker would, fixed, retested and documented for your premarket submission.

From the threat model

We start from the threats and controls in your threat model and test whether each control holds, so results trace straight back to your design documentation.

A report FDA can review

Reports state our independence and expertise, scope, duration, methods and results, the elements FDA's guidance asks penetration test reports to include.

Fixed, then proven fixed

A retest of your fixes is included, so your submission shows each finding assessed, remediated or justified, and confirmed.

Illustrative example. The device, interface and statuses are a composite for explanation only and do not describe any client. Testing uses test units agreed in the rules of engagement, never devices in clinical use.

Text version of the exhibit
  1. Control: your threat model says the device accepts firmware only from the manufacturer. FDA's guidance includes software binaries among the information a device should be able to authenticate.
  2. Test: testers build a modified firmware image and push it to a test unit over the Bluetooth Low Energy update service, alongside fuzz testing of the BLE inputs.
  3. Finding: the test unit boots the modified firmware, so authenticity is not verified. The finding is rated Critical.
  4. Fix: we describe code signing with signature verification on the device, which also supports your update and patch processes under section 524B(b)(2).
  5. Retest: the modified image is rejected and the fix is confirmed; residual risk is recorded in your risk file.
  6. Submitted: the report (tester independence and expertise, scope, duration, methods, results and traceability to the threat model) goes into your premarket submission.

03Requirement to evidence

What cybersecurity evidence does FDA expect in a 510(k)?

What FDA's guidance and section 524B ask for, what ioSENTRIX tests for each, and the evidence that goes into your submission.

ExpectationWhat FDA asksWhat ioSENTRIX testsEvidence in your submission
Threat modelGuidanceThreat modeling of the device system, with traceability to the risk assessment, SBOM and testing.Threat modeling or review of yours, covering every interface and update path.Threat model and traceability matrix
Risk assessmentGuidanceCybersecurity risk assessment and a security risk management report.Exploitability assessment of identified risks, proven on test units.Findings mapped to risk controls
SBOM524B(b)(3)A software bill of materials, including commercial, open-source and off-the-shelf components, required for cyber devices.SBOM review and software composition analysis of firmware binaries.SBOM validation and known-vulnerability notes
Security testingGuidanceSecurity requirements, threat mitigation and vulnerability testing (fuzzing, attack surface, chaining, code analysis) and penetration testing.Embedded device penetration testing, fuzzing of wireless and wired inputs, app and cloud testing.Reports with independence, scope, duration, methods and results
Findings assessmentGuidanceYour assessment of every finding, with rationale for any fix not implemented or deferred, and plans for future releases.Risk-ranked findings with fix guidance, then a retest of your fixes.Findings log, retest results and deferral rationale
Postmarket524B(b)(1), (b)(2)For cyber devices: a plan to monitor, identify and address postmarket vulnerabilities, and updates and patches for known unacceptable vulnerabilities.Testing of the update mechanism, retests of patches and testing after significant changes.Update-path results and patch retests

Summarized from FDA, "Cybersecurity in Medical Devices: Quality Management System Considerations and Content of Premarket Submissions," final guidance issued February 3, 2026 (nonbinding recommendations), and section 524B of the FD&C Act as described in that guidance. Orientation, not regulatory advice. FDA decides what evidence is sufficient.

04Timing

When should you test a medical device for FDA?

Throughout development, as FDA recommends, with an independent penetration test before the design is frozen for submission.

  1. Design (SPDF)

    Security requirements and architecture built into the secure product development framework.

    Design review
  2. Threat model

    Every interface, update path and connected system modeled and risk-assessed.

    Threat model
  3. Test

    Fuzzing, SBOM and binary analysis, and an independent penetration test on test units.

    Manual testing
  4. Fix and retest

    Fix guidance for each finding, then a retest of your fixes.

    Retest included
  5. Submission package

    Reports and traceability ready for your 510(k), De Novo or PMA.

    Evidence pack
  6. Postmarket

    Testing of updates and patches, and after significant changes.

    Ongoing
PremarketEvidence for the submission

Threat model, risk assessment, SBOM and security testing documentation, including penetration test reports, in the premarket submission.

PostmarketKeep the device cybersecure

For cyber devices, the 524B(b)(1) plan and timely updates and patches, with testing that confirms each fix.

05Evidence pack

What's in a medical device cybersecurity evidence pack?

The testing documentation your regulatory team needs for the submission, in one place.

  1. Tester independence and expertise

    Who tested, their qualifications and their independence from your developers.

  2. Scope, duration and methods

    Device, firmware, interfaces, apps and cloud in scope, dates and the methods used.

    ANSI/ISA 62443-4-1NIST SP 800-115
  3. Findings with proof

    Each finding with evidence, exploitability, potential impact and steps to reproduce.

  4. SBOM and binary analysis

    Software composition results and known vulnerabilities in third-party components.

  5. Retest results

    Fixes retested and recorded, with rationale noted for any deferred finding.

  6. Traceability

    Each result traced to the threat model and risk assessment.

    Threat modelRisk file524B

06Independently verified

★★★★★
“The team at ioSENTRIX is professional and highly skilled at their craft.”
Awwab A.SVP, Chief Information Security Officer · Verified G2 review ↗
★★★★★
“We were impressed with ioSENTRIX's ability to independently validate the security of our customer-facing product.”
Zeehasham R.Data Scientist, Security Operations · Insurance · Verified Clutch review ↗

08Insights

Read before you scope your device test

09FAQ

Medical device cybersecurity questions

Short answers to what device makers and regulatory teams ask us most.

Ask us something else

Does the FDA require penetration testing for a 510(k)?

FDA's final guidance, Cybersecurity in Medical Devices: Quality Management System Considerations and Content of Premarket Submissions (February 3, 2026), recommends that security testing documentation be included in premarket submissions, including 510(k)s, and lists penetration testing among the types of testing to consider. FDA asks that penetration test reports state the testers' independence and technical expertise, the scope, duration and methods of testing, and the results. The guidance contains nonbinding recommendations; for cyber devices, section 524B of the FD&C Act adds statutory requirements.

What is a cyber device under section 524B?

Section 524B(c) of the FD&C Act defines a cyber device as a device that includes software validated, installed or authorized by the sponsor as a device or in a device, has the ability to connect to the internet, and contains technological characteristics that could be vulnerable to cybersecurity threats. FDA's guidance treats firmware and programmable logic as software, and counts any means of connecting to the internet, intended or not.

What does section 524B require of cyber device manufacturers?

A submission for a cyber device must include information FDA requires to show it meets section 524B(b): a plan to monitor, identify and address postmarket cybersecurity vulnerabilities and exploits, including coordinated vulnerability disclosure (524B(b)(1)); processes and procedures that provide reasonable assurance the device and related systems are cybersecure, including updates and patches (524B(b)(2)); and a software bill of materials (524B(b)(3)).

What security testing does FDA recommend for medical devices?

The guidance lists, among others: testing of security requirements; threat mitigation testing against your threat models; vulnerability testing such as abuse and misuse cases, malformed and unexpected inputs (robustness and fuzz testing), attack surface analysis, vulnerability chaining, known vulnerability scanning, software composition analysis of binaries and static and dynamic code analysis; and penetration testing.

Does the penetration tester need to be independent?

FDA asks manufacturers to state who performed the testing and what level of independence the testers have from the developers who designed the device, and notes that third parties may sometimes be needed to ensure appropriate independence. For third-party reports, FDA asks for the original report. ioSENTRIX tests as an independent third party.

What happens to findings we decide not to fix before submission?

FDA asks for your assessment of every finding, including the rationale for not implementing or deferring a fix. For remediation deferred to a future release, the submission should contain plans for that release, including the vulnerabilities it will address and anticipated timelines.

Does ioSENTRIX prepare or submit the 510(k)?

No. ioSENTRIX provides the cybersecurity testing, threat modeling, SBOM review and reports that go into your premarket submission. Your regulatory team prepares and submits it, and FDA makes the clearance decision.

Ready when you are

Get premarket cybersecurity evidence that holds up

Tell us about your device, its interfaces and your submission date. We will help you scope the right testing and plan it before design freeze.

  • Written scope and timeline before testing starts
  • Retest of fixes included
  • Reports built around FDA's premarket guidance
Scope your medical device test

Takes about a minute.